33 KV - Class Containerized Substation Seaworthy Housing Convenient Maintenance

Brand Name : Pearl Electric Co.,Ltd.
Model Number : PEO-S, S9~13
Certification : KEMA, CE, CCC, ISO9001
Place of Origin : China
MOQ : 1 unit
Price : USD/RMB
Payment Terms : T/T, L/C
Supply Ability : 8000 units per year
Delivery Time : 35~50days ex-work
Packaging Details : Seaworthy wooden packing
Capacity : 30kVA~10MVA or Customized
Rated H. V. : 30 kv or Customized
Rated L. V. : 0.4kv or Customized
Vector Group : Dyn11 or Customized
Impedence : 4%-6% or Customized
Cooling : ONAN/ONAF or Customized
Contact Now

30 kV - Class , High Mechanical Strength , Container Substation Transformer , Seaworthy Housing


Introduction


1 Features

  1. High safety performance
  2. Functional maturation & Reliable performance
  3. Rich structure
  4. Convenient maintenance
  5. Low noise
  6. Wonderful weather resistance
  7. No-leakage

2 Applied Standards

IEC 60076


Specifications:
Rated H.V.:20 (10.5, 11, 6.3, 6) kV, ±2×2.5%
Vector GroupDyn11/Yyn0
Rated L.V.:0.4/0.433 kV
Capacity:50~4000
No-load Loss:0.13~3.20kW
Load Loss0.60~21.5kW
No-load Current:0.6~2.3%
Impedance Voltage:4/4.5/5.5%
Tap-changingOn-load / Off-load Tap-changing
Cooling Method:ONAN/ONAF
Reference StandardsIEC60076
Notes: The above specifications may be customized according to customer's requirement.
Features & Advantages
1. Low loss, low noise and high reliability.
2. Excellent dynamic thermal stability and high over-load capacity.
3. Simulation analysis was carried out for the core mould design, thus to greatly reduce noise level. Simulated lightning impulse wave process was carried out for HV winding mould design, thus to greatly improve product's anti-lightning impulse capability.

After the circuit-breaker is switched off, please check the equipment in the following respects:

  1. Check the conditions of upper and lower contactors. Check the screw and nuts. Check the insulation part.
  2. Check whether there is any short-circuit within the arc extinguish chamber.
  3. Check the magnetic-trip armature.

Notices when checking instrument transformer:


During operation, please ensure the secondary circuit should have no short-circuit. If there is short-circuit at the secondary circuit, large short-circuit current is generated, which may damage the transformer or causes explosions. The secondary circuit should not be open circuit. Otherwise high-voltage may be generated, which may endanger the safety of both the equipment and operation personnel. Because the iron core may also burn out the instrument transformer. Therefore, before operating on the secondary circuit, please short circuit the secondary circuit terminal.


Capacitor fault processing:


First switch off the switch before the capacitor and make discharging for the capacitor group. Considering the capacitor may not be fully discharged and there are still residual current, the operating personnel must put on insulation gloves. Then, make short circuit between the two polarities of the capacitor and discharge the residual current. Then, dismantle and replace the capacitor.



Product Tags:

containerized substation

      

containerised substation

      
China Customized Inflatable Bumper Ball Game Bubble Adult Grass CE supplier

33 KV - Class Containerized Substation Seaworthy Housing Convenient Maintenance Images

Inquiry Cart 0
Send your message to this supplier
 
From:
Enter your email please.
To: Pearl Electric Co.,Ltd.
Subject:
Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0